🚀 Genuine products, vast inventory, swift shipping!
QUINT-PS/1AC/24DC/10 Phoenix Contact | Power Supply Unit
QUINT-PS/1AC/24DC/10 Phoenix Contact | Power Supply Unit
Technical Specifications:
Manufacturer:
Phoenix Contact
Product No.:
QUINT-PS/1AC/24DC/10
Condition:
In Stock
Product Type:
Power Supply Unit
Product Origin:
DE
Weight:
1100g
Shipping port:
Xiamen
Warranty:
12 months
Phoenix Contact Model QUINT-PS/1AC/24DC/10 Power Supply Unit
Technical Specifications
Dimensions
Width with Alternative Assembly | 122 mm |
Height with Alternative Assembly | 130 mm |
Depth with Alternative Assembly | 63 mm |
Ambient Conditions
Degree of Protection | IP20 |
Ambient Temperature (Operation) | -25 °C ... 70 °C (> 60 °C Derating: 2.5 %/K) |
Ambient Temperature (Start-up Type Tested) | -40 °C |
Ambient Temperature (Storage/Transport) | -40 °C ... 85 °C |
Max. Permissible Relative Humidity (Operation) | ≤ 95 % (at 25 °C, non-condensing) |
Climatic Class | 3K3 (in acc. with EN 60721) |
Degree of Pollution | 2 |
Installation Height | 5000 m |
Input Data
Nominal Input Voltage Range | 100 V AC ... 240 V AC / 110 V DC ... 250 V DC |
Input Voltage Range | 85 V AC ... 264 V AC / 90 V DC ... 350 V DC (UL 508: ≤ 300 V DC) |
Dielectric Strength Maximum | 300 V AC |
AC Frequency Range | 45 Hz ... 65 Hz |
Frequency Range DC | 0 Hz |
Discharge Current to PE | < 3.5 mA |
Current Consumption |
2.2 A (120 V AC) 1.3 A (230 V AC) 2.5 A (110 V DC) 1.2 A (220 V DC) |
Nominal Power Consumption | 302 VA |
Inrush Surge Current | < 15 A |
Mains Buffering |
> 36 ms (120 V AC) > 36 ms (230 V AC) |
Input Fuse | 10 A (slow-blow, internal) |
Choice of Suitable Circuit Breakers | 10 A ... 20 A (AC: Characteristics B, C, D, K) |
Type of Protection | Transient surge protection |
Protective Circuit/Component | Varistor, gas-filled surge arrester |
Output Data
Nominal Output Voltage | 24 V DC ±1 % |
Setting Range of the Output Voltage (USet) | 18 V DC ... 29.5 V DC (> 24 V DC, constant capacity restricted) |
Nominal Output Current (IN) | 10 A (-25 °C ... 60 °C, UOUT = 24 V DC) |
POWER BOOST (IBoost) | 15 A (-25°C ... 40°C permanent, UOUT = 24 V DC) |
Selective Fuse Breaking (ISFB) | 60 A (12 ms) |
Residual Ripple | < 50 mVPP (with nominal values) |
Output Power | 240 W |
Typical Response Time | < 0.15 s |
Maximum Power Dissipation in No-Load Condition | 9.1 W |
Power Loss Nominal Load Max. | 22 W |
General Information
Net Weight | 1.1 kg |
Efficiency | > 92.5 % (for 230 V AC and nominal values) |
Insulation Voltage Input/Output |
4 kV AC (type test) 2 kV AC (routine test) |
Insulation Voltage Input / PE |
3.5 kV AC (type test) 2 kV AC (routine test) |
Insulation Voltage Output / PE | 500 V DC (routine test) |
Protection Class | I |
Degree of Protection | IP20 |
MTBF (IEC 61709, SN 29500) |
> 940000 h (25 °C) > 530000 h (40 °C) > 230000 h (60 °C) |
Mounting Position | Horizontal DIN rail NS 35, EN 60715 |
Assembly Instructions |
Alignable: PN ≥50%, 5 mm horizontally, 15 mm next to active components, 50 mm vertically Alignable: PN <50%, 0 mm horizontally, 40 mm vertically top, 20 mm vertically bottom |
Connection Data, Input
Connection Method | Pluggable screw connection |
Conductor Cross Section Solid |
Min. 0.2 mm² Max. 2.5 mm² |
Conductor Cross Section Flexible |
Min. 0.2 mm² Max. 2.5 mm² |
Conductor Cross Section AWG |
Min. AWG 16 Max. AWG 12 |
Stripping Length | 7 mm |
Screw Thread | M3 |
Related Tags :