IC220ALG220 | GE Fanuc | Analog Input Module
IC220ALG220 | GE Fanuc | Analog Input Module
Technical Specifications:
Manufacturer:
GE
Product No.:
IC220ALG220
Condition:
In Stock
Product Type:
VersaPoint I/O Module
Product Origin:
USA
Weight:
200g
Shipping port:
Xiamen
Warranty:
12 months
Overview
The Emerson / GE Fanuc IC220ALG220 is an analog input module designed for measuring voltage or current signals in various industrial applications. It features 15-bit resolution and supports connection to both 2-wire and 3-wire sensors. The module requires an I/O Terminal Strip (IC220TBK061), which is sold separately.
Key Features
- Two Analog Inputs: Single-ended inputs for voltage or current signals.
- Flexible Sensor Connection: Compatible with 2- and 3-wire sensors.
-
Current Ranges:
- 0 to 20 mA
- ±20 mA
- 4 to 20 mA
-
Voltage Ranges:
- 0 to 10 V
- ±10 V
- Independent Channel Configuration: Each channel can be configured independently.
- Resolution: 15-bit resolution, independent of representation format and measuring range.
- Fast Data Update: Process data updates for both channels in a maximum of 1.5 ms.
- Diagnostic Indicators: Built-in indicators for real-time diagnostics.
Ordering Information
Part Number | Description |
---|---|
IC220ALG220 | Analog Input Module (15 Bit, Voltage/Current, 2 Channels) |
IC220TBK061 | I/O Terminal Strip with Shield (order separately) |
Technical Specifications
Specification | Details |
---|---|
Housing Dimensions | 12.2 mm x 120 mm x 71.5 mm |
Connection Style | 2- and 3-wire |
Power for Sensors | External power supply |
Operating Temperature | -25°C to +55°C (-13°F to +131°F) |
Storage Temperature | -25°C to +85°C (-13°F to +185°F) |
Operating Humidity | 75% average; >85% requires measures |
Storage Humidity | 75% average |
Degree of Protection | IP 20 (IEC 60529) |
Class of Protection | Class 3 (VDE 0106, IEC 60536) |
Power Consumption | Approximately 0.63W typical |
Analog Input Specifications
Feature | Specification |
---|---|
Number of Inputs | 2 (single-ended) |
Input Design | EN 61131-2, Type 1 |
Voltage Input Range | 0 to 10 V, ±10 V |
Current Input Range | 0 to 20 mA, ±20 mA, 4 to 20 mA |
Process Data Update | < 1.5 ms |
Input Resistance (Voltage) | > 1 MΩ |
Input Resistance (Current) | 50 Ω (shunt) |
Common Mode Rejection | 90 dB minimum, 110 dB typical |
Error Tolerances
Error Type | Voltage Inputs | Current Inputs |
---|---|---|
Offset Error | ±0.03% | ±0.03% |
Gain Error | ±0.05% | ±0.10% |
Total Error | ±0.15% | ±0.20% |
Safety and Isolation
- Electrical Isolation: Requires separate power supplies for bus module and sensors to ensure isolation between logic level and I/O area.
- Surge Protection: Integrated surge voltage suppressor diodes for protection.
Error Messages to the Control System
- Internal Voltage Supply Breakdown: Yes
- I/O Error/User Error: Yes, reported through process data input words.
Applications
- Industrial Automation: Ideal for measuring various analog signals in automation systems.
- Process Control: Suitable for continuous monitoring of process variables.
- Machine Control: Used in controlling and monitoring machinery and equipment.