Technical Specifications:
Manufacturer:
Emerson
Product No.:
A6370D
Condition:
In Stock
Product Type:
Overspeed Protection Monitor
Product Origin:
USA
Weight:
490g
Shipping port:
Xiamen
Warranty:
12 months
Technical Specifications
Sensor Voltage Supply | |
Nominal Supply Voltage: | -24.5 V ±1.5V DC, short-circuit proof, galvanically separated |
Max. Current: | 35 mA |
Signal Input, Eddy Current & Hall Element Sensors | |
Input Signal Voltage Range: | 0 V to 26 V (+/-), protected against reverse polarity |
Limit Range: | ± 48 V |
Frequency Range: | 0 to 20 kHz |
Input Resistance (Typical): | 100 kΩ |
Signal Input, Magnetic (VR) Sensors | |
Input Signal Voltage Range: | Min. 1 Vpp, max. 30 V RMS |
Frequency Range: | 0 to 20 kHz |
Input Resistance (Typical): | 18 kΩ |
Digital Input (Backplane) | |
Number of Inputs: | 4 (Galvanically separated with common ground of all digital inputs) (Test Value 1, Test Value 2, Enable Test Values, Reset Latch) |
Logic Low Level: | 0 V to 5 V |
Logic High Level: | 13 V to 31 V, open |
Input Resistance (Typical): | 6.8 kΩ |
Current Output (Backplane) | |
Number of Outputs: | 2 Electrically isolated with common ground |
Range: | 0/4 to 20 mA or 20 to 4/0 mA |
Accuracy: | ±1% of full scale |
Maximum Load: | <500 Ω |
Max. Output Current: | 20 mA |
Digital Output (Backplane) | |
Number of Outputs: | 7 (Short-circuit proof) Out 1 to Out 6, Channel Ok (COK) |
Logic Low Level: | < 100 mV |
Logic High Level: | -2 V |
System Supply Voltage: | Max. Current 25 mA |
Pulse Output (Backplane) | |
Number of Outputs: | 3 Open-Collector-Emitter, Current limited, galvanically separated |
Max. Voltage: | 31.2 V |
Max. Current: | 16 mA @ 24 V |
Frequency Range: | 0 to 20 kHz |
Pulse Output (Front Panel) | |
Number of Outputs: | 1 (Short-circuit-proof) |
Voltage: | 0 to 5 V TTL-Signal |
Frequency Range: | 0 to 20 kHz |
Output Impedance (Typical): | 10 kΩ |
Sens. Output (Front Panel) | |
Number of Outputs: | 1 (Short-circuit-proof) |
Voltage: | 0 to 3.9 V, Factor 0.15 ± 3% |
Frequency Range: | 0 to 20 kHz |
Output Impedance (Typical): | 10 kΩ |
Communication | |
USB: | Configuration Interface, USB type B |
RS 485: | Max. 32 devices Baud Rate: 38400, 57600, 115200 Baud |
Profibus DP (A6370D/DP only): | Max. 31 devices Data transmission rate: up to 12 Mbit/s |
Reaction Time | |
Speed: | < Measuring Time + 8 ms |
Typical Reaction Time Speed at 3000 min-1: | Mode “1x per revolution”: 35 ms Mode “Automatically”: 12.5 ms |
Rotational Direction: | < 3 * Period time of input signal + 8 ms |
Operating Temperature: | -20°C to +65°C (-4°F to 149°F) |
Storage Temperature: | -40°C to +70°C (-40°F to 158°F) |
Relative Humidity: | 5 to 95% Non-condensing |
Vibration: | 0.15mm (0.591in), 20 m/s², 58 to 62Hz to 150Hz according to IEC 60068-2-6 |
Shock: | 100 m/s², 6ms according to IEC 60068-2-27 |
Operating Altitude: | <5000 m above sea level |
Weight: | Approx. 490g (1.080 lbs) |