Technical Specifications:

Manufacturer:
Allen-Bradley
Product No.:
1442-DR-5850
Condition:
In Stock
Product Type:
Eddy Current Probe
Product Origin:
USA
Weight:
250g
Shipping port:
Xiamen
Warranty:
12 months

1442 Series Probe Systems Technical Specifications

Standard Calibration

  • Calibration Standard: AISI 4140 (JIS SCM440) steel flat surface

Electrical Specifications

  • Maximum Output Voltage (approx): -23V DC (applies at 25 °C (77 °F) with -24V DC power supply, load resistance 10 kΩ, and AISI 4140 (JIS SCM440) steel flat surface target (thickness ≥ 5 mm))
  • Probe/Sensor Abnormal Output Voltage (approx): -0.6V DC (probe/sensor OPEN or SHORT)
  • Current Consumption (10 kΩ load, max): -15 mA
  • Output Noise (approx): 20 mV peak-to-peak + power supply noise
  • Power Supply: -24V DC

Physical Specifications

  • Cable Diameter (approx): 2.7 mm or 3.6 mm (0.11 in. or 0.14 in.)
  • Connector Diameter (approx): 7.1 mm (0.28 in.)
  • Connector Diameter (Armored, approx): 5.8 mm (0.23 in.)
  • System Cable Length: 5 m or 9 m (16.40 ft or 29.53 ft) nominal
  • Probe Integral Cable Variance: +30% / -0%
  • Extension Cable Variance: +20% / -0%

Driver Specifications

  • Driver Insulation Resistance: ≥ 100 MΩ @ 500V DC (between terminals and mounting plate)
  • Isolation Voltage (Driver): 50V (continuous), Basic Insulation Type, terminals to mounting plate; Type tested at 500V AC for 60 s
  • Wiring Category: 2 - on signal ports (Refer to Industrial Automation Wiring and Grounding Guidelines, publication 1770-4.1)
  • Wire Size (Driver): 0.75…1.25 mm² (18…16 AWG) shielded stranded-copper wire rated at 90 °C (194 °F), or greater, 1.2 mm (3/64 in.) insulation max
  • Driver Mass (approx): 200 g (7.0 oz.)

Environmental Specifications

Temperature

  • Operating (Hazardous Area): -40…+80°C (-40…+176 °F)
  • Operating (IEC 60068-2-1, IEC 60068-2-2, IEC 60068-2-14):
    • Probe: -40…+80°C (-40…+176 °F)
    • Driver: -40…+177°C (-40…+350 °F)
    • Connector: -40…+80°C (-40…+176 °F)

Humidity

  • Relative Humidity (IEC 60068-2-30): 30…95% RH (non-condensing, non-submerged)
  • Probe/Sensor Body: 100% RH

Vibration

  • Vibration (IEC 60068-2-6): 1 g @ 10…150 Hz

Immunity and Emissions

  • Emissions (CISPR11, IEC 61000-6-4): Class A
  • ESD Immunity (IEC 61000-4-2): 6 kV contact discharges, 8 kV air discharges
  • Radiated RF Immunity (IEC 61000-4-3):
    • 10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz
    • 3V/m with 1 kHz sine-wave 80% AM from 1400…2000 MHz
    • 1V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz
  • EFT/B Immunity (IEC 61000-4-4): ±1 kV at 5 kHz on shielded signal ports
  • Surge Transient Immunity (IEC 61000-4-5): ±1 kV line-earth (CM) on shielded signal ports
  • Conducted RF Immunity (IEC 61000-4-6): 10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
  • Magnetic Field Immunity (IEC 61000-4-8): 30 A/m long duration at 50 Hz

General Specifications