🚀 Genuine products, vast inventory, swift shipping!
07 KP 93 ABB 07KP93 Communication Process MOBUS
07 KP 93 ABB 07KP93 Communication Process MOBUS
Technical Specifications:
Manufacturer:
ABB
Product No.:
07-KP-93
Condition:
In Stock
Product Type:
Communication Process MOBUS
Product Origin:
Switzerland
Weight:
450g
Shipping port:
Xiamen
Warranty:
12 months
Features
- · The RCOM 07 KP 90 GJR5253200R1161 R303 communication module can be planned as RCOM master or slave.
- · A network may have up to 254 RCOM slaves (max. 8 slaves if using MasterPiece 200, max. 30 slaves in case of dial-up mode).
- · The RCOM protocol is compatible with MP200/1 with DSCA 180A. All RCOM services are available (cold start, warm start, normalization, clock synchronization, write data, read data, event polling).
- · The RCOM interface for connection of the modem complies with EIA RS-232. It can also be used as an EIA RS-485 interface.
- · An additional operator interface (CONSOLE) complying with EIA RS-232 is provided as a commissioning aid (indication of the communication sequence, planning telephone numbers, etc.)
- · Software clock; time can be used in the PLC program.
- · Differences between RCOM and RCOM+, see "System technology / External couplers / 07 KP 90". All other features of RCOM which are not mentioned in the chapter “Differences” apply correspondingly for RCOM+.
- · The function block RCOM+ can be used with the communication module 07 KP 90 from index b up.
General Data
Parameter | Specification |
---|---|
Number of serial interfaces | 2 |
Number of parallel interfaces | 1 networking interface for connecting to the Advant Controller 31 basic unit |
Operating and error displays | 6 LEDs: RUN, ERR, Supply, RxD, TxD, BLK |
Conductor cross section for the removable terminal blocks | max. 2.5 mm² |
Power Supply for 07 KP 90 R303
Parameter | Specification |
---|---|
Rated supply voltage | 24 V DC |
Power dissipation | typ. 2.5 W |
Max. current consumption with rated voltage | 210 mA |
Max. current consumption with a supply voltage of 30 V | 170 mA |
Protection against reversed terminal connection | Yes |
Serial Interfaces RCOM and CONSOLE
Parameter | Specification |
---|---|
Interface standard | EIA RS-232 or EIA RS-485 (RCOM only) |
Electrical isolation | Yes, RCOM interface with respect to the rest of the unit |
Potential differences | No earthing potential differences arise between the 07 KP 90 R303 and the peripheral units connected to RCOM and CONSOLE. They are supplied from the switch-gear cabinet mains socket. |
Transmission speed (Baud rate) | RCOM: 300...19200 Baud, CONSOLE: 9600 Baud |
Terminal assignment and description of the interfaces RCOM, CONSOLE | See page 7.1-8 onwards |
LED Displays
LED | Description |
---|---|
Supply voltage present (Supply) | 1 green LED |
Fatal or serious error occurred (ERR) | 1 red LED |
Ready for RCOM communication (running) (RUN) | 1 green LED |
Interface signals RxD, TxD | 2 yellow LEDs |
Protocol status BLK | 1 yellow LED |
Mechanical Data
Parameter | Specification |
---|---|
Mounting | On DIN rail in accordance with DIN EN 50022–35, 15 mm deep. The DIN rail is located in the middle between the upper and the lower edges of the module. |
Fastening | By screws using 4 M4 screws |
Width x height x depth | 140 x 120 x 85 mm |
Wiring method | By removable terminal blocks with screw-type terminals, max. 2.5 mm² |
Weight | 450 g |