Technical Specifications:

Manufacturer:
ABB
Product No.:
07-KP-93
Condition:
In Stock
Product Type:
Communication Process MOBUS
Product Origin:
Switzerland
Weight:
450g
Shipping port:
Xiamen
Warranty:
12 months

Features

  • · The RCOM 07 KP 90 GJR5253200R1161 R303 communication module can be planned as RCOM master or slave.
  • · A network may have up to 254 RCOM slaves (max. 8 slaves if using MasterPiece 200, max. 30 slaves in case of dial-up mode).
  • · The RCOM protocol is compatible with MP200/1 with DSCA 180A. All RCOM services are available (cold start, warm start, normalization, clock synchronization, write data, read data, event polling).
  • · The RCOM interface for connection of the modem complies with EIA RS-232. It can also be used as an EIA RS-485 interface.
  • · An additional operator interface (CONSOLE) complying with EIA RS-232 is provided as a commissioning aid (indication of the communication sequence, planning telephone numbers, etc.)
  • · Software clock; time can be used in the PLC program.
  • · Differences between RCOM and RCOM+, see "System technology / External couplers / 07 KP 90". All other features of RCOM which are not mentioned in the chapter “Differences” apply correspondingly for RCOM+.
  • · The function block RCOM+ can be used with the communication module 07 KP 90 from index b up.

General Data

Parameter Specification
Number of serial interfaces 2
Number of parallel interfaces 1 networking interface for connecting to the Advant Controller 31 basic unit
Operating and error displays 6 LEDs: RUN, ERR, Supply, RxD, TxD, BLK
Conductor cross section for the removable terminal blocks max. 2.5 mm²

Power Supply for 07 KP 90 R303

Parameter Specification
Rated supply voltage 24 V DC
Power dissipation typ. 2.5 W
Max. current consumption with rated voltage 210 mA
Max. current consumption with a supply voltage of 30 V 170 mA
Protection against reversed terminal connection Yes

Serial Interfaces RCOM and CONSOLE

Parameter Specification
Interface standard EIA RS-232 or EIA RS-485 (RCOM only)
Electrical isolation Yes, RCOM interface with respect to the rest of the unit
Potential differences No earthing potential differences arise between the 07 KP 90 R303 and the peripheral units connected to RCOM and CONSOLE. They are supplied from the switch-gear cabinet mains socket.
Transmission speed (Baud rate) RCOM: 300...19200 Baud, CONSOLE: 9600 Baud
Terminal assignment and description of the interfaces RCOM, CONSOLE See page 7.1-8 onwards

LED Displays

LED Description
Supply voltage present (Supply) 1 green LED
Fatal or serious error occurred (ERR) 1 red LED
Ready for RCOM communication (running) (RUN) 1 green LED
Interface signals RxD, TxD 2 yellow LEDs
Protocol status BLK 1 yellow LED

Mechanical Data

Parameter Specification
Mounting On DIN rail in accordance with DIN EN 50022–35, 15 mm deep. The DIN rail is located in the middle between the upper and the lower edges of the module.
Fastening By screws using 4 M4 screws
Width x height x depth 140 x 120 x 85 mm
Wiring method By removable terminal blocks with screw-type terminals, max. 2.5 mm²
Weight 450 g