Technical Specifications:

Manufacturer:
Bently Nevada
Product No.:
133442-01
Condition:
In Stock
Product Type:
I/O Module
Product Origin:
USA
Weight:
460g
Shipping port:
Xiamen
Warranty:
12 months

Specifications

Inputs

  • Signal:

    • Each 3500/50M Tachometer Module accepts up to two transducer signals from proximity probe transducers or magnetic pickups.
    • Input signal range: +10.0 V to -24.0 V (signals exceeding this range are limited internally by the module).
    • Input impedance:
      • Standard: 20 kΩ
      • TMR (Triple Modular Redundancy): 40 kΩ
      • Internal Barrier: 7.15 kΩ
  • Power consumption: 5.8 watts, typical

  • Transducers:

    • Accepts 1 to 2 proximity transducer signals
    • Restrictions may apply to magnetic pickups (see Warning on page 2).

Outputs

  • Front Panel LEDs:

    • OK LED: Indicates proper operation of the 3500/50M Tachometer Module.
    • TX/RX LED: Indicates communication with other modules in the 3500 rack.
    • Bypass LED: Indicates the module is in Bypass Mode.
  • Buffered Transducer Outputs:

    • One coaxial connector per channel on the front of the module.
    • Buffered outputs are available at the I/O module via Euro style connectors.
    • Output Impedance: 550 Ω
  • Transducer Power Supply: 24 Vdc, 40 mA maximum per channel

  • Recorder Outputs:

    • Current: +4 to +20 mA proportional to module full-scale range (rpm or rpm/min), provided individually for each channel.
    • Monitor operation unaffected by short circuits on recorder outputs.
    • Voltage Compliance (current output): 0 to +12 Vdc range across load, Load resistance 0 to 600 Ω
    • Resolution: 0.3662 µA per bit ±0.25% error at room temperature, ±0.7% error over temperature range
    • Update rate: Approximately 100 ms

Signal Conditioning

  • Specified at +25 ºC (+77 ºF)

  • Speed Input:

    • Supports 1 to 255 events per revolution for Rotor Acceleration and Zero Speed channel types.
    • Other channel types support 0.0039 to 255 events per revolution.
    • Maximum full scale range: 99,999 rpm
    • Maximum input frequency: 20 kHz
    • Minimum input frequency:
      • Proximity transducers: 0.0167 Hz (1 rpm for 1 event per revolution)
      • Passive magnetic pickups: 3.3 Hz
  • RPM Accuracy:

    • Less than 100 rpm: ± 0.1 rpm
    • 100 to 10,000 rpm: ±1 rpm
    • 10,000 to 99,999 rpm: ± 0.01% of true shaft speed
  • RPM/Min Accuracy: ± 20 rpm/min

Transducer Conditioning

  • Auto Threshold: For any input above 0.0167 Hz (1 rpm for 1 event/revolution). Minimum signal amplitude for triggering is 1 volt peak-to-peak.

  • Manual Threshold: User selectable from +9.5 Vdc to -23.5 Vdc. Minimum signal amplitude for triggering is 500 millivolts peak-to-peak.

  • Hysteresis: User selectable from 0.2 to 2.5 volts

Alarms

  • Alarm Setpoints:

    • Alarm 1 levels can be set for each measured value.
    • Alarm 2 setpoints can be set for any two measured values.
    • Setpoints are adjustable from 0 to 100% of full scale for each measured value.
  • Alarm Time Delays:

    • Alarm 1 Time Delay: 1 to 60 seconds in 1-second intervals
    • Alarm 2 Time Delay: 1 to 60 seconds in 0.1-second intervals

Proportional Values

  • Speed measurements used to monitor a machine. The module returns values like:
    • Rotor Speed, Speed1, Speed Band, Peak Speed2, Rotor Speed 2, etc.
    • Values for different channel types like Rotor Acceleration, Zero Speed, Reverse Rotation.

Physical

  • I/O Modules (internal barrier):
    • Dimensions (Height x Width x Depth): 241.3 mm x 24.4 mm x 163.1 mm (9.50 in x 0.96 in x 6.42 in)
    • Weight: 0.46 kg (1.01 lb)

Environmental Limits

  • Operating Temperature:
    • With Internal/External Termination I/O Module: -30 ºC to +65 ºC (-22 ºF to +150 ºF)
  • Storage Temperature: -40 ºC to +85 ºC (-40 ºF to +185 ºF)
  • Humidity: 95% Non-condensing

Hazardous Area Approvals

  • With I/O module ordering options without internal barriers:
    • Ex nC [L] IIC, Class I, Division 2
    • AEx nC IIC, Class I, Division 2, Groups A, B, C, D, T4 @ Ta = -20 °C to +65 °C (-4 °F to +150 °F) per drawing 149243

Compliance and Certifications

  • EMC Standards:

    • EN 61000-6-2 Immunity for Industrial Environments
    • EN 61000-6-4 Emissions for Industrial Environments
    • EN 55011/CISPR 11 ISM Equipment
  • European Community Directives:

    • EMC Directive 2004/108/EC
    • Electrical Safety Standards: EN 6110-1
    • Low Voltage Directive 2006/95/EC

Ordering Considerations

  • External Termination Blocks cannot be used with Internal Termination I/O modules.
  • When ordering I/O Modules with External Terminations, order External Termination Blocks and cables separately.
  • Use Bussed External Termination Blocks with TMR I/O modules only.