🚀 Originálne produkty, obrovské zásoby, rýchle dodanie!
Yokogawa SSC60D-S2512 Safety Control Unit
Yokogawa SSC60D-S2512 Safety Control Unit
Technical Specifications:
Manufacturer:
Yokogawa
Product No.:
SSC60D-S2512
Condition:
In Stock
Product Type:
Safety Control Unit
Product Origin:
99
Weight:
8500g
Shipping port:
Xiamen
Warranty:
12 months
Module Configuration
Component | Description |
---|---|
Power Supply Module | (SPW481, SPW482 or SPW484): 2 modules |
Processor Module | (S2CP471 or SCP461): 2 modules for dual-redundant configuration. (*1) |
Memory Protection | Application program is stored in flash memory. Processor module operation data is stored in NVRAM (nonvolatile memory). |
Temperature Adaptability | A fan unit is provided for high temperature use where the safety control units (SSC60S-F/SSC60D-F) ambient temperature exceeds 40 °C. |
Communications Interface | Vnet/IP interface: Dual-redundant. ESB bus interface: Dual-redundant. |
Communication on Vnet/IP
Items | Specifications |
---|---|
Communication Speed | 100 Mbps, Full duplex |
Connection | UTP cable (CAT5e or higher), RJ45 connector |
Interface | 100Base-TX compliance |
Max. Distance | 100 m (distance between SSC60S/SSC60D and Layer 2 switch) |
Connecting Safety Node Units
Component | Description |
---|---|
Number of Safety Node Units | Up to 13 safety node units can be connected using SEC402 ESB bus coupler module and adding CFS1350 Node Expansion Package. Up to 9 safety node units can be connected using SEC401 ESB bus coupler module. |
Installation Requirements | ESB bus coupler modules (SEC402/SEC401) should be mounted on 7-th and 8-th slots. ESB bus can be extended by Optical ESB bus repeater modules. |
Number of I/O Modules Mounted
Items | Specifications |
---|---|
Per Safety Control Unit | Up to eight |
Per SCS (with SEC402 and CFS1350) | Up to 110 |
Per SCS (with SEC401) | Up to 78 |
Power Requirements
Voltage | Description |
---|---|
100 to 120 V AC, 50 or 60 Hz | |
220 to 240 V AC, 50 or 60 Hz | |
24 V DC |
Power Consumption
Model | 100 to 120 V AC | 200 to 240 V AC | 24 V DC |
---|---|---|---|
SSC60S-S/SSC60D-S | 200 VA | 230 VA | 5.5 A |
SSC60S-F/SSC60D-F | 240 VA | 290 VA | 7.0 A |
Battery
Component | Part No. | Replacement Period |
---|---|---|
S2CP471 | S9450FE | Three years under the average ambient temperature of 30 °C or less. |
SCP461 | S9185FA | Three years under the average ambient temperature of 30 °C or less. |
Weight
Model | Weight |
---|---|
SSC60S-S | Approximately 7.9 kg |
SSC60S-F | Approximately 13 kg |
SSC60D-S | Approximately 8.5 kg |
SSC60D-F | Approximately 13 kg |
Suffix Codes
Code | Description |
---|---|
-S | Standard Type (-20 to 40 °C) (with ISA Standard G3 ) |
-F | Wide range temperature (-20 to 70 °C) type (with Fan unit and ISA Standard G3) |
-2 | Dual-redundant power supply |
-5 | With no explosion protection |
-E | With explosion protection |
-1 | 100-120 V AC power supply |
-2 | 220-240 V AC power supply |
-4 | 24 V DC power supply |
-1 | CFS1300 Safety Control Function License (R3) |
-2 | Without Safety Control Function License (R4.01 or later) |
Dimension: 482.6 mm x 266 mm x 207 mm
Note: The SCS is composed of a safety control unit, safety node units and an ESB bus connecting them.