Bently Nevada 125736-01 3500/92 Modbus RS232/RS422 I/O Module

Bently Nevada 125736-01 3500/92 Modbus RS232/RS422 I/O Module

Technical Specifications:

Manufacturer:
Bently Nevada
Product No.:
125736-01
Condition:
In Stock
Product Type:
Modbus RS232/RS422 I/O Module
Product Origin:
USA
Weight:
440g
Shipping port:
Xiamen
Warranty:
12 months

Description

The Bently Nevada 125736-01 is a Communication Gateway I/O Module designed as a Modbus RS232/RS422 I/O Module. This module retains the original 3500/90's communication interfaces, protocols, and other features, except for the primary value Modbus registers. It includes a Configurable Modbus Register Utility, replicating the functionality of the primary value Modbus registers.

Specifications

  • Part Number: 125736-01
  • Manufacturer: Bently Nevada
  • Operating Temperature: -30 to +65 degrees Celsius
  • Storage Temperature: -40 to +85 degrees Celsius
  • Dimensions (H x W x D): 241 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
  • Weight: 0.44 kg (0.96 lb)
  • Humidity: 95%, non-condensing
  • Availability: In Stock
  • Function: Communication Gateway I/O Module
  • Country of Manufacture: United States (USA)

Features

  • Communication Capabilities:

    • Extensive communication of all rack monitored values and statuses for integration with process control and automation systems via Ethernet TCP/IP and serial (RS232/RS422/485) communications.
    • Communication over Ethernet with 3500 Rack Configuration Software and Data Acquisition Software.
    • RJ45 Ethernet connection for 10BASE-T star configuration Ethernet networks.
    • Supports original communication interfaces, protocols, and features, except for the primary value Modbus registers.
    • TCP/IP capabilities on Ethernet.
    • Serial communications capabilities (RS232/RS422/RS485).
    • Modbus Register Configurable Utility.
  • Outputs:

    • OK LED: Indicates when the system is operating properly.
    • TX/RX LED: Indicates when the system is communicating with other modules in the 3500 rack.
  • Input Data Types:

    • Data from other modules in the rack is collected via a high-speed internal network, including current measured values with time stamps, module statuses, and current alarm statuses.
    • The exact data types returned are determined by the module type and channel configuration.
    • Update Time: The data collection rate is determined by rack configuration but will not exceed one second for all modules in the rack.
  • Protocol:

    • BNC Host Protocol.
    • TCP/IP communication with 3500 Configuration Software and Data Acquisition and Display Software.
    • Modbus protocol according to the AEG Modicon PI-MBUS-300 Reference Manual. Transmission mode is Remote Terminal Unit (RTU).