🚀 Γνήσια προϊόντα, τεράστιο απόθεμα, γρήγορη αποστολή!
REF611 ABB - Feeder Protection and Control
REF611 ABB - Feeder Protection and Control
Technical Specifications:
Manufacturer:
ABB
Product No.:
REF611
Condition:
In Stock
Product Type:
Feeder Protection and Control
Product Origin:
USA
Weight:
4100g
Shipping port:
Xiamen
Warranty:
12 months
Technical Specifications for REF611
Dimensions
-
Width:
- Frame: 177 mm
- Case: 164 mm
-
Height:
- Frame: 177 mm (4U)
- Case: 160 mm
- Depth: 201 mm (153 + 48 mm)
-
Weight:
- Complete protection relay: 4.1 kg
- Plug-in unit only: 2.1 kg
Power Supply
-
Nominal Auxiliary Voltage:
- Type 1: 100, 110, 120, 220, 240 V AC (50 and 60 Hz)
- Type 2: 24, 30, 48, 60 V DC; 48, 60, 110, 125, 220, 250 V DC
- Maximum Interruption Time in Auxiliary DC Voltage: 50 ms at Un
-
Auxiliary Voltage Variation:
- Type 1: 38...110% of Un (38...264 V AC)
- Type 2: 50...120% of Un (12...72 V DC); 80...120% of Un (38.4...300 V DC)
- Start-up Threshold: 19.2 V DC (24 V DC × 80%)
-
Burden of Auxiliary Voltage Supply:
- Type 1 (DC): <12.5 W (nominal)/<15.0 W (max.)
- Type 1 (AC): <13.5 W (nominal)/<16.0 W (max.)
- Type 2 (DC): <10.2 W (nominal)/<10.8 W (max.)
- Ripple in the DC Auxiliary Voltage: Max 15% of the DC value (at frequency of 100 Hz)
- Fuse Type: T4A/250 V
Energizing Inputs
- Rated Frequency: 50/60 Hz
-
Current Inputs:
- Rated current (In): 0.2/1 A or 1/5 A
- Thermal Withstand Capability:
- Continuously: 4 A or 20 A
- For 1 s: 100 A or 500 A
- Dynamic Current Withstand:
- Half-wave value: 250 A or 1250 A
- Input Impedance: <100 mΩ or <20 mΩ
-
Residual Voltage Input:
- Rated Voltage: 60...210 V AC
- Voltage Withstand:
- Continuous: 240 V AC
- For 10 s: 360 V AC
- Burden at Rated Voltage: <0.05 VA
Binary Inputs
- Operating Range: ±20% of the rated voltage
- Rated Voltage: 24...250 V DC
- Current Drain: 1.6...1.9 mA
- Power Consumption: 31.0...570.0 mW
- Threshold Voltage: 16...176 V DC
- Reaction Time: <3 ms
Signal Outputs
- Rated Voltage: 250 V AC/DC
- Continuous Contact Carry: 5 A
-
Make and Carry:
- For 3.0 s: 15 A
- For 0.5 s: 30 A
-
Breaking Capacity (Control-circuit time constant L/R<40 ms):
- 48/110/220 V DC: 1 A/0.25 A/0.15 A
-
Minimum Contact Load:
- 100 mA at 24 V AC/DC
- 10 mA at 5 V AC/DC (Signal Outputs and IRF Output)
Communication Protocols
- Supported Protocols: IEC 61850, Modbus RTU/ASCII, Modbus TCP/IP
-
Interfaces:
- Ethernet: 100BASE-TX (RJ-45), 100BASE-FX (LC)
- Serial: RS-485
- Redundancy Protocols: HSR, PRP, RSTP
Related Tags :