Μετάβαση στις πληροφορίες προϊόντος
1 από 2

🚀 Γνήσια προϊόντα, τεράστιο απόθεμα, γρήγορη αποστολή!

Bently Nevada 136180-01 3500/92 Communication Gateway Module

Bently Nevada 136180-01 3500/92 Communication Gateway Module

Technical Specifications:

Manufacturer:
Bently Nevada
Product No.:
136180-01
Condition:
In Stock
Product Type:
Communication Gateway Module
Product Origin:
USA
Weight:
820g
Shipping port:
Xiamen
Warranty:
12 months

Description:

The Bently Nevada 3500/92 Communication Gateway module provides extensive communication capabilities of all rack monitored values and statuses for integration with process control and other automation systems using both Ethernet TCP/IP and serial (RS232/RS422/RS485) communications capabilities. It also permits Ethernet communications with 3500 Rack Configuration Software and Data Acquisition Software. Supported protocols include Modicon® Modbus® (via serial communications), Modbus/TCP (a variant of serial Modbus used for TCP/IP Ethernet communications), and proprietary Bently Nevada protocol for communication with 3500 Rack Configuration and Data Acquisition Software packages. The Ethernet connection to the 3500/92 is an RJ45 connection for 10BASE-T star configuration Ethernet networks.

Technical Specifications:

  • Inputs:

    • Power Consumption:
      • 5.0 watts typical with Modbus RS232/RS422 I/O Module.
      • 5.6 watts typical with Modbus RS485 I/O Module.
    • Data Types:
      • Collects data from other modules in the rack, such as current proportional values with time stamp, module statuses, and current alarm statuses via a high-speed internal network.
    • Update Time:
      • The data collection rate depends on rack configuration but will not exceed 1 second for all modules in the 3500 rack.
  • Outputs:

    • Front Panel LEDs:
      • OK LED: Indicates when the 3500/92 is operating properly.
      • TX/RX LED: Indicates when the 3500/92 is communicating with other modules in the 3500 rack.
  • Protocols:

    • BNC Host Protocol: Communication with 3500 Configuration Software and 3500 Data Acquisition and Display Software over Ethernet TCP/IP.
    • Modbus: Based on AEG Modicon PI-MBUS-300 Reference Manual. Uses Remote Terminal Unit (RTU) transmission mode. Modbus is a registered trademark of Modicon, Inc.
    • Ethernet Communication Link: Ethernet, 10Mbps, and conforms to IEEE802.3.
    • Protocol: Ethernet TCP/IP frame and Modbus/TCP.
    • Connection: RJ-45 (telephone jack style) for 10BASE-T Ethernet cabling.
  • Environmental Limits:

    • Main Module:
      • Operating Temperature: -30 °C to +65 °C (-22 °F to +150 °F).
      • Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F).
      • Humidity: 95%, non-condensing.
    • I/O Module:
      • Operating Temperature: 0 °C to +65 °C (+32 °F to +150 °F).
      • Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F).
      • Humidity: 95%, non-condensing.