Technical Specifications:

Manufacturer:
Allen-Bradley
Product No.:
1783-BMS10CL
Condition:
In Stock
Product Type:
Stratix 5700 Switches
Product Origin:
USA
Weight:
1250g
Shipping port:
Xiamen
Warranty:
12 months

1783-BMS10CL AB Stratix 5700 Switches      Technical Specifications

Mechanical

Width 9.14 cm
Height 12.95 cm
Depth 11.67 cm
Approximate weight 1.25 kg
Screw torque, ground terminal, maximum 0.96 Nm
Screw torque, power and alarm terminals 0.23 Nm

Electrical

Number of ports 10/100 Mbps RJ45 8
Number of combination-ports RJ45/Mini GBIC 2
Layer 2 No
Layer 3 No
Manageable Yes
Power consumption, maximum 17 W
Power dissipation 17 W
Firmware type Lite
Isolation voltage 50 V
Power consumption at 24V DC, 40 ˚C 12.5 W
Total number of ports 10
Wire size, alarm connection 0.5 mm²
Wire size, DC power connection 0.5 mm²
Wire size, ethernet connection RJ45 connector according to IEC 60603-7
Mounting method DIN rail (top hat rail)
Ethernet Yes
Protection type Alarm not rated
Alarm relay at 30V DC 1 A
Alarm relay at 48V DC 0.5 A
Maximum insulation, DC power connection 1.2 mm
Power input at 12 - 48V DC, class 2/SELV 0.5 A
Wire size, ground connection 4 mm²
Wire strip length, alarm connection 6.3±0.5 mm
Wire strip length, DC power connection 6.3±0.5 mm
Wiring category on console and alarm ports 3
Wiring category on DC power ports 2
Wiring category on Ethernet ports 2

Environmental

Degree of protection (IP) IP30
Housing base material Open-style
Nominal position T4
Temperature, surrounding air, maximum 60 °C
EFT/B immunity for IEC 61000-4-4 at 100 kHz on DC power ports ±2 kV
EFT/B immunity for IEC 61000-4-4 at 100 kHz on Ethernet ports ±1 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on alarm ports ±2 kV
EFT/B immunity for IEC 61000-4-4 at 5 kHz on Ethernet ports ±2 kV
Emissions, CISPR11 (IEC 61000-6-4) Class A
ESD immunity, IEC 61000-4-2, air discharges 15 kV
ESD immunity, IEC 61000-4-2, contact discharges 8 kV
Radiated RF immunity, IEC 61000-4-3 with 1 kHz sine-wave 80% AM from 1000 - 2700 MHz 10 Kg/Km
Radiated RF immunity, IEC 61000-4-3 with 200 Hz 50% pulse 100% AM at 900 MHz 20 Kg/Km
Shock, non-operating, IEC 60068-2-27 (test Ea, unpackaged shock) 55 g
Shock, operating, IEC 60068-2-27 (test Ea, unpackaged shock) 30 g
Surge transient immunity, IEC 61000-4-5, line-earth (CM) on Ethernet ports ±2 kV
Temperature, operating, IEC 60068-2-1 (test Ad, operating, cold) -40 °C
Temperature, operating, IEC 60068-2-