Bently Nevada 163179-02 3500/61 Temperature Monitor (with recorders)
Bently Nevada 163179-02 3500/61 Temperature Monitor (with recorders)
Technical Specifications:
Description
The Bently Nevada 163179-02 3500/61 Temperature Monitor provides six channels of temperature monitoring and accepts both Resistance Temperature Detector (RTD) and Thermocouple (TC) inputs. The module conditions these inputs and compares them against user-programmable alarm setpoints. Unlike the 3500/60, the 3500/61 includes recorder outputs for each of its six channels.
The user can configure the module for either RTD or TC temperature measurements using the 3500 Rack Configuration Software. Different I/O modules are available in RTD/TC non-isolated or TC isolated versions, with the TC isolated version offering 250 Vdc of channel-to-channel isolation.
Technical Specifications
Inputs:
- Accepts 1 to 6 RTD or TC transducer signals.
- Input Impedance: 10 MΩ for each lead input.
Power Consumption:
- 3500/61: Nominal consumption of 9 watts.
Transducers:
TCs:
- Type E: -100 °C to +1000 °C (-148 °F to +1832 °F).
- Type J: -18 °C to +760 °C (+0 °F to +1400 °F).
- Type K: -18 °C to +1370 °C (+0 °F to +2498 °F).
- Type T: -160 °C to +400 °C (-256 °F to +752 °F).
RTDs:
- 100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00385): -200 °C to +850 °C (-328 °F to +1562 °F).
- 100Ω 3-wire & 4-wire platinum RTD (alpha = 0.00392): -200 °C to +700 °C (-328 °F to +1292 °F).
- 120Ω 3-wire & 4-wire nickel RTD: -80 °C to +260 °C (-112 °F to +500 °F).
- 10Ω 3-wire & 4-wire copper RTD: -100 °C to +260 °C (-148 °F to +500 °F).
Outputs:
- Front Panel LEDs for OK, TX/RX, and Bypass indications.
- Recorder outputs: +4 to +20 mA proportional to monitor full-scale.
- Voltage Compliance (current output): 0 to +12 Vdc across a load of 0 to 600 Ω.
Signal Conditioning:
- Resolution: 1 °C or 1 °F.
- Accuracy for RTDs and TCs (except 10Ω Copper RTDs): ±3 °C at 25 °C (±5.4 °F at 77 °F).
Alarms:
- Setpoints adjustable from 0 to 100% of full-scale for each measured value.
- Alarm Time Delays: 1 to 60 seconds for Alert, 1 to 60 seconds for Danger.
Environmental Limits:
- Operating Temperature: -30 °C to +65 °C (-22 °F to +150 °F) with Internal/External Termination I/O Modules.
- Storage Temperature: -40 °C to +85 °C (-40 °F to +185 °F).
Physical:
- Monitor Module Dimensions: 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in).
- Weight: 0.91 kg (2.0 lb).
- I/O Modules Dimensions: 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in).
- Weight: 0.45 kg (1.0 lb).
Compliance and Certifications
- EMC Directive 2014/30/EU
- Electrical Safety: EN 61010-1
- RoHS Directive 2011/65/EU
- Designed to meet IEC 62443 Cyber Security
- Maritime: DNV GL, ABS Rules for Condition of Classification
- Functional Safety: SIL 2
- Hazardous Area Approvals: CSA/NRTL/C, ATEX/IECEx