Technical Specifications:
Description:
The Bently Nevada 140734-02 3500/42M Proximitor®/Seismic Monitor is a 4-channel monitor designed to accept input from proximity and seismic transducers. It conditions these signals to provide various vibration and position measurements, and compares the conditioned signals with user-programmable alarms. Each of the monitor's channels can be programmed using the 3500 Rack Configuration Software to perform multiple functions such as Radial Vibration, Thrust Position, Differential Expansion, Eccentricity, REBAM®, Acceleration, Velocity, Shaft Absolute, and Circular Acceptance Region. Channels are programmed in pairs, allowing them to perform up to two functions simultaneously.
The primary purpose of the 3500/42M monitor includes:
- Machinery protection by continuously comparing monitored parameters against configured alarm setpoints.
- Providing essential machine information for both operations and maintenance personnel.
Technical Specifications:
Inputs:
- Signal: Accepts 1 to 4 proximity, velocity, or acceleration transducer signals.
-
Input Impedance:
- Standard I/O: 10 kΩ (Proximitor® and Acceleration Inputs).
- TMR I/O: Effective impedance of 50 kΩ with three Bussed TMR I/O channels wired in parallel to one transducer.
Power Consumption:
- 7.7 Watts, typical.
Sensitivity:
-
Radial Vibration, Thrust, Eccentricity, Shaft Absolute, Direct:
- 3.94 mV/µm (100 mV/mil) or 7.87 mV/µm (200 mV/mil).
-
Differential Expansion:
- 0.394 mV/µm (10 mV/mil) or 0.787 mV/µm (20 mV/mil).
-
REBAM®:
- 40 mV/µm (1000 mV/mil) or 80 mV/µm (2000 mV/mil).
-
Acceleration and Acceleration2:
- 10 mV/(m/s²) (100 mV/g).
-
Velocity and Velocity2:
- 20 mV/(mm/s) pk (500 mV/(in/s) pk), 5.8 mV/(mm/s) pk (145 mV/(in/s) pk), or 4 mV/(mm/s) pk (100 mV/(in/s) pk).
Outputs:
-
Front Panel LEDs:
- OK LED: Indicates proper operation.
- TX/RX LED: Indicates communication with other modules in the 3500 rack.
- Bypass LED: Indicates Bypass Mode.
-
Buffered Transducer Outputs:
- One coaxial connector for each channel, short-circuit protected.
- Output Impedance: 550 Ω
- Transducer Power Supply: -24 Vdc
-
Recorder:
- +4 to +20 mA, values proportional to monitor full-scale, individual recorder values for each channel.
- Voltage Compliance (current output): 0 to +12 Vdc range across load, load resistance 0 to 600 Ω.
-
Resolution:
- 0.3662 µA per bit, ±0.25% error at room temperature, ±0.7% error over temperature range.
- Update rate 100 ms or less.
Signal Conditioning:
-
Radial Vibration Frequency Response:
- Direct filter: User-programmable, 4 Hz to 4000 Hz or 1 Hz to 600 Hz.
- Gap filter: -3 dB at 0.09 Hz.
- Not 1X filter: 60 cpm to 15.8 times running speed.
- 1X and 2X Vector filter: Valid for machine speeds of 60 cpm to 60,000 cpm.
-
Accuracy:
- Direct and Gap: ±0.33% of full-scale typical, ±1% maximum.
- 1X and 2X: ±0.33% of full-scale typical, ±1% maximum.
- Smax: ±5% maximum.
- Not 1X: ±3% for machine speeds less than 30,000 cpm, ±8.5% for speeds greater than 30,000 cpm.
Thrust and Differential Expansion Frequency Response:
- Direct filter: -3 dB at 1.2 Hz.
- Gap filter: -3 dB at 0.41 Hz.
- Accuracy: ±0.33% of full-scale typical, ±1% maximum.
Acceleration Frequency Response:
- Without Filter: RMS 10 to 30,000 Hz, Peak 3 to 30,000 Hz.
- With Integration: RMS 10 to 9,155 Hz, Peak 10 to 9,155 Hz.
- Filter Quality: 4-pole (80 dB per decade, 24 dB per octave).
- Accuracy: ±0.33% of full-scale typical, ±1% maximum.
Velocity and Velocity II Frequency Response:
- RMS: 10 to 5,500 Hz, -3 dB.
- Peak or Peak-to-Peak: 3 to 5,500 Hz, -3 dB.
- Filter Quality: High-Pass 2-pole, Low-Pass 4-pole.
- Accuracy: ±0.33% of full-scale typical, ±1% maximum.
Alarms:
- User-set Alert and Danger setpoints adjustable from 0 to 100% of full-scale.
- Alarm Time Delays programmable from 1 to 60 seconds for Alerts and 0.1 to 60 seconds for Danger.
Static Values:
- Radial Vibration: Direct, Gap, 1X Amplitude, 1X Phase Lag, 2X Amplitude, 2X Phase Lag, Not 1X Amplitude, Smax Amplitude.
- Thrust Position: Direct, Gap.
- Differential Expansion: Direct, Gap.
- Eccentricity: Peak-to-peak, Gap, Direct Minimum, Direct Maximum.
- REBAM®: Spike, Element, Rotor, Direct, Gap, 1X Amplitude, 1X Phase Lag.
- Acceleration: Direct (RMS or peak Acceleration, RMS or peak Velocity, Band-pass peak Acceleration, Band-pass peak Velocity).