Məhsul məlumatlarına keçin
1 of 1

🚀 Orijinal məhsullar, geniş inventar, sürətli çatdırılma!

Allen-Bradley 1756-IF4FXOF2F ControlLogix Fast Analog Module

Allen-Bradley 1756-IF4FXOF2F ControlLogix Fast Analog Module

Technical Specifications:

Manufacturer:
Allen-Bradley
Product No.:
1756-H4FXOF2F
Condition:
In Stock
Product Type:
ControlLogix Fast Analog Module
Product Origin:
USA
Weight:
500g
Shipping port:
Xiamen
Warranty:
12 months

Product Description:

The Rockwell Automation Allen-Bradley (AB) 1756-IF4FXOF2F ControlLogix Fast Analog Module features 4 current-voltage inputs and 2 current-voltage outputs, housed in a 36-pin configuration. It provides high-speed, precise analog signal processing for demanding industrial applications.

Technical Specifications

Electrical

  • Input, current: Yes
  • Input, voltage: Yes
  • Input, resistor: No
  • Input, resistance thermometer: No
  • Input, thermocouple: No
  • Input signal, configurable: Yes
  • Output, current: No
  • Output, voltage: No
  • Output signal configurable: No
  • Analogue inputs configurable: Yes
  • Analogue outputs configurable: No
  • Type of electric connection: Screw-/spring clamp connection
  • Output range: ±10V, 0…20 mA
  • Terminal block torque specifications: 1756-TBCH: 0.5 Nm (4.4 lb.in)
  • Input conversion method: Successive approximation
  • Module keying: Electronic, software configurable
  • Offset drift: 50 µV/°C, 1 µV/°C
  • Output conversion method: R-Ladder DAC, monotonicity with no missing codes
  • Drive capability: Voltage: >2000 Ω, Current: 0...750 Ω
  • Input range: ±10V, 0...10V, 0...5V, 0...20 mA
  • Data format: Integer mode (left justified, 2's complement) IEEE 32-bit floating point
  • Wire category: 2 - on signal ports
  • Overvoltage protection: Voltage: 30V DC, input, Current: 8V AC/DC, input, Output: 24V DC
  • Module error: Input: 0.2% of range, Voltage: 0.2% of range, output, Current: 0.3% of range, output
  • Gain drift with temperature: Voltage: 25 ppm/°C maximum, input, Current: 35 ppm/°C maximum, input, Voltage: 25 ppm/°C maximum, output, Current: 50 ppm/°C maximum, output
  • Voltage and current ratings: Backplane: 375 mA @ 5.1V DC, 100 mA @ 24V DC, Analog inputs: -10...+10V, 4...20 mA, Analog outputs: -10...+10V, 4...20 mA
  • Module scan time: 300 µs minimum
  • Thermal dissipation: Voltage: 14.66 BTU/hr, Current: 16.02 BTU/hr
  • Current draw: 375 mA @ 5.1V, 100 mA @ 24V
  • Power dissipation: Voltage: 4.3 W, Current: 4.7 W
  • Resolution:
    • Input: Approx 14 bits across ±10.5V DC (21V total), ±10.5V range: 1.3 mV/bit, 14 bit effective, 0...10.5V range: 1.3 mV/bit, 13 bit effective, 0...5.25V range: 1.3 mV/bit, 12 bit effective, Approx 12 bits across 21 mA, 0...21 mA range: 5.25 μA/bit
    • Output
  • Wire size: Single wire connection (1756-TBCH): 0.33...2.1 mm² (22...14 AWG) solid or stranded shielded copper wire, rated at 105 °C (221 °F) or greater, 1.2 mm (3/64 in.) insulation maximum, Single wire connection (1756-TBS6H): 0.33...2.1 mm² (22...14 AWG) solid or stranded
  • Calibrated accuracy:
    • Input: 0.05% of range immediately after calibration, Better than 0.1% of range within calibration interval @ 25 °C (77 °F)
    • Output: 0.05% of range immediately after calibration, Better than 0.1% of range within calibration interval @ 25 °C (77 °F)
  • Open circuit detection time:
    • Input: Positive full-scale reading within 1 s
    • Output: Current output only (output must be set to >0.1 mA)
  • Suitable for safety functions: No
  • Update period for all channels (RPI), min: 1 ms
  • Number, output: 2 high-speed voltage or current
  • Number, input: 4 high-speed, submillisecond, differential
  • Short circuit protection: Electronically current limited to 21 mA or less
  • Output settling time: <2 ms to 95% of final value with resistive loads

Environmental

  • Surrounding air temperature, max: 60 °C
  • North American temperature code: T4A
  • Power consumption: 4.3 W
  • Emissions: IEC 61000-6-4
  • ESD immunity: 6 kV contact discharges, 8 kV air discharges
  • EFT/B immunity: ±2 kV at 5 kHz on shielded signal ports
  • Relative humidity: 5...95% noncondensing
  • Conducted RF immunity: 10V rms with 1 kHz sine wave 80% AM from 150 kHz...80 MHz on shielded signal ports
  • Surge transient immunity: ±2 kV line-earth (CM) on shielded signal ports
  • Operating temperature: 0 °C <Ta <60 °C (32 °F <Ta <140 °F)
  • Radiated RF immunity:
    • 10 V/m with 1 kHz sine-wave 80% AM from 80...2000 MHz
    • 10 V/m with 200 Hz 50% pulse 100% AM @ 900 MHz
    • 10 V/m with 200 Hz 50% pulse 100% AM @ 1890 MHz
    • 3 V/m with 1 kHz sine-wave 80% AM from 2000...2700 MHz
    • 3 V/m with 1 kHz sine-wave 80% AM from 2700...6 GHz
  • Nonoperating temperature: -40 °C

Mechanical

  • RTB keying: User-defined mechanical
  • Vibration: 2 G @ 10...500 Hz
  • Shock: Operating: 30 G, Non operating: 50 G
  • Slot width: 1

Certification

  • Calibration interval: Input: 12 months, Output: 12 months
  • ATEX temperature code: T4
  • IECEx temperature code: T4

General Specifications

  • Repeatability: ±1 least significant bit (LSB)  

Input Specifications

  • Input impedance: Voltage: >1 MΩ, Current: 249 Ω

Power

  • Isolation voltage: 250V (continuous), Reinforced insulation type, inputs and outputs to backplane, No isolation between individual inputs or outputs

Construction

  • Enclosure type rating: None (open-style)