3500/42 125672-02 Proximitor/Seismic Monitor Bently Nevada
3500/42 125672-02 Proximitor/Seismic Monitor Bently Nevada
Technical Specifications:
Inputs
Signal: Accepts from 1 to 4 signal inputs.
Input Impedance:
- Standard I/O: 10 kΩ
- TMR I/O (Proximitor and Acceleration Inputs):
- Bussed Transducer Configuration: 50 kΩ
- Discrete Transducer Configuration: 150 kΩ
Power: Nominal consumption of 7.7 watts
Sensitivity:
Type | Sensitivity |
---|---|
Radial Vibration | 3.94 mV/µm (100 mV/mil) or 7.87 mV/µm (200 mV/mil) |
Thrust | 3.94 mV/µm (100 mV/mil) or 7.87 mV/µm (200 mV/mil) |
Eccentricity | 3.94 mV/µm (100 mV/mil) or 7.87 mV/µm (200 mV/mil) |
Differential Expansion | .394 mV/µm (10 mV/mil) or .787 mV/µm (20 mV/mil) |
Acceleration | 10 mV/(m/s²) (100 mV/g) |
Velocity | 20 mV/(mm/s) pk (500 mV/(in/s) pk), 5.8 mV/(mm/s) pk (145 mV/(in/s) pk), 4 mV/(mm/s) pk (100 mV/(in/s) pk) |
Outputs
Front Panel LED’s:
- OK LED: Indicates when the 3500/42 is operating properly.
- TX/RX LED: Indicates when the 3500/42 is communicating with other modules in the 3500 rack.
- Bypass LED: Indicates when the 3500/42 is in Bypass Mode.
Buffered Transducer Outputs: The front of each monitor has one coaxial connector for each channel. Each connector is short circuit protected.
Output Impedance: 550 Ω
Transducer Supply Values: -24 Vdc
Recorder: +4 to +20 mA. Values are proportional to monitor full scale. Individual recorder values are provided for each channel. Monitor operation is unaffected by short circuits on recorder outputs.
Voltage Compliance (current output): 0 to +12 Vdc range across load. Load resistance is 0 to 600 Ω.
Resolution: 0.3662 µA per bit
Accuracy: ±0.25 % error at room temperature, -0.66 to +0.70 % error over temperature range, updated rate 100 ms or less.
Signal Conditioning
Specified at +25° C (77° F)
Radial Vibration Frequency Response:
- Direct Filter: User-programmable for 4 to 4,000 Hz or 1 to 600 Hz.
- Gap Filter: -3 dB at .09 Hz.
- Not 1X Filter: 60 cpm to 16 times running speed. Constant Q notch filter. Minimum rejection in stopband of –34.9 dB.
- Smax: 0.125 to 16 times running speed. Constant Q Filter. Minimum rejection in stopband of -57.7 dB.
- 1X & 2X Vector Filter: Valid for machine speeds of 60 to 60,000 cpm. Minimum rejection in stopband of -57.7 dB. Minimum Signal Amplitude for Phase measurement is 42.7 mV.
Accuracy:
- Direct and Gap: Within ±0.33 % of full scale typical, ±1 % maximum.
- 1X & 2X: Within ±0.33 % of full scale typical, ±1 % maximum.
- Smax: Within ±5 % maximum.
- Not 1X: ±3 % for machine speeds less than 30,000 cpm. ±8.5 % for machine speeds greater than 30,000 cpm.
Thrust and Differential Expansion
Frequency Response:
- Direct Filter: -3 dB at 1.2 Hz.
- Gap Filter: -3 dB at 0.41 Hz.
Accuracy: Within ±0.33 % of full scale typical, ±1 % maximum.
EIPP Monitor
Frequency Response:
- Direct Filter: -3 dB at 15.6 Hz.
- Gap Filter: -3 dB at 0.41 Hz.
Accuracy: Within ±0.33 % of full scale typical, ±1 % maximum.