Technical Specifications:
Description
The 3500/22M Transient Data Interface (TDI) is the interface between the 3500 monitoring system and compatible software (System 1 Condition Monitoring and Diagnostic software and 3500 System Configuration software). The TDI combines the function of a 3500/20 Rack Interface Module (RIM) with the data collection capability of a communication processor such as TDXnet. The TDI resides in the slot adjacent to the power supplies of a 3500 rack. It interfaces with M series monitors (3500/40M, 3500/42M, etc.) to continuously collect steady state and transient dynamic (waveform) data and pass this data through an Ethernet link to the host software. Refer to the Compatibility section at the end of this document for more information.
Static data capture capability is standard with the TDI. However, using an optional Channel Enabling Disk will allow the TDI to capture dynamic and high-resolution transient data as well. The TDI incorporates the communication processor function within the 3500 rack. Although the TDI provides certain functions common to the entire rack, it is not part of the critical monitoring path and has no effect on the proper, normal operation of the overall monitor system for automatic machinery protection. Every 3500 rack requires one TDI or RIM, which always occupies Slot 1 (next to the power supplies).
Specifications
Inputs
- Power Consumption: 10.5 Watts
Data
- Front Panel USB-B
- 10Base-T/100Base-TX I/O: 10Base-T or 100Base-TX Ethernet, autosensing
- 100Base-FX I/O: 100Base-FX Fiber-Optic Ethernet
Outputs
Front Panel LEDs
- OK LED: Indicates when the 3500/22M is operating properly
- TX/RX LED: Indicates when the 3500/22M is communicating with the other modules in the rack
- TM LED: Indicates when the 3500 rack is in Trip Multiply mode
- CONFIG OK LED: Indicates that the 3500 rack has a valid configuration
I/O Module
OK Relay Function
- Indicates when the 3500 rack is operating normally or when a fault has been detected within the rack. User can select either an “OPEN” or “CLOSED” contact to annunciate a NOT OK condition. This relay always operates as “Normally Energized”.
Ratings
- Standard OK Relay is rated to 5A @ 24 Vdc/120 Vac, 120 Watts/600 VA Switched Power (maximum)
- OK Relay with gold-plated contacts is rated down to 1 mA @ 1 Vdc (minimum)
- Arc Protection: Arc suppressors are provided.
Controls
- Front Panel Rack Reset Button: Clears latched alarms and Timed OK Channel Defeat in the rack. Performs same function as “Rack Reset” contact on I/O module
- Address Switch: Used to set the rack address: 127 possible addresses
- Configuration Keylock: Used to place 3500 rack in either “RUN” mode or “PROGRAM” mode. RUN mode allows for normal operation of the rack and locks out configuration changes. PROGRAM mode allows for normal operation of the rack and also allows for local or remote rack configuration. The key can be removed from the rack in either position, allowing the switch to remain in either the RUN or PROGRAM position. Locking the switch in the RUN position allows you to restrict unauthorized rack reconfiguration. Locking the switch in PROGRAM position allows remote reconfiguration of a rack at any time.
I/O Module System Contacts
- Trip Multiply: Used to place 3500 rack in Trip Multiply
Maximum Current
Environmental Limits
-
TDI Module, 10Base-T/100Base-TX I/O, and 100Base-FX I/O
- Operating Temperature: -30°C to +65°C (-22°F to +149°F)
- Storage Temperature: -40°C to +85°C (-40°F to +185°F)
- Humidity: 95%, non-condensing
Battery Life
- Powered TDI: 38 years @ 50°C (122°F)
- Unpowered TDI: 12 years @ 50°C (122°F)
Physical
TDI Module Dimensions (Height x Width x Depth):
- 241.3 mm x 24.4 mm x 241.8 mm (9.50 in x 0.96 in x 9.52 in)
- Weight: 0.91 kg (2.0 lbs)
I/O Modules Dimensions (Height x Width x Depth):
- 241.3 mm x 24.4 mm x 99.1 mm (9.50 in x 0.96 in x 3.90 in)
- Weight: 0.20 kg (0.44 lbs)
Rack Space Requirements
- TDI Module: 1 full-height front slot
- I/O Modules: 1 full-height rear slot
Ordering Information
3500/22M TDI Module and I/O
-
3500/22M-01-02-00
- 3500/22M: 3500/22M Transient Data Interface Module
- -01: Transient Data Interface Type is Standard (use for standard monitoring applications)
- -02: I/O Module Type is 100Base-FX (Fiber Optic) Ethernet
- -00: None Agency Approval