330130-075-11-05 | Bently Nevada Armored Extension Cable
Manufacturer:
Bently Nevada
Product No.:
330130-075-11-05
Condition:
In Stock
Product Type:
Extension Cable
Product Origin:
USA
Weight:
772g
Shipping port:
Xiamen
Warranty:
12 months
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Overview
The Bently Nevada 330130-075-11-05 is a high-quality extension cable designed for optimal performance in various industrial applications. Manufactured in the U.S.A., this product features a robust construction with optional Certificate of Origin (COO).
Technical Specifications
- Brand: Bently Nevada
- Model: 330130-075-11-05
-
Suffix Definitions:
- 075: Cable length option (7.5 meters)
- 11: Cable type (Armored FluidLoc)
- 05: Approval classifications (CSA, ATEX, IECEx)
Performance Characteristics:
- Linear Range: 2 mm (80 mils), beginning at approximately 0.25 mm (10 mils) from the target.
- Sensitivity: Less than 2 mV change in output voltage per volt change in input voltage.
- Maximum Length: 305 meters (1,000 feet) between the sensor and the monitor.
- Installation Recommendations: Use 3 conductor shielded triad cable and tinned field wiring.
-
Resistance:
- RCORE: 1.65 ± 0.25 Ω @ 7.5 m
- RJACKET: 0.49 ± 0.10 Ω @ 7.5 m
- Power Requirements: -17.5 Vdc to -26 Vdc
- Output Resistance: 50 Ω
- Extension Cable Capacitance: 69.9 pF/m (21.3 pF/ft)
FAQ
-
Q1: What is the maximum cable length for this extension cable?
The maximum cable length is 305 meters (1,000 feet) between the 3300 XL Proximitor Sensor and the monitor. -
Q2: Can this cable handle turbine oil exposure?
It is not recommended to use silicone tape for applications exposed to turbine oil. -
Q3: What are the approval ratings for this cable?
The cable has CSA, ATEX, and IECEx approvals, ensuring compliance with strict safety standards. -
Q4: What is the sensitivity of the cable?
The sensitivity is less than a 2 mV change in output voltage per volt change in input voltage.