Honeywell TC-ODD321 Experion DC Output Module
Manufacturer:
Honeywell
Product No.:
TC-ODD321
Condition:
In Stock
Product Type:
Output Module
Product Origin:
USA
Weight:
570g
Shipping port:
Xiamen
Warranty:
12 months
UBEST – Trusted Global Automation Parts Supplier
We offer a wide range of in-stock industrial automation spare parts. All products come with a 12-month warranty and a 30-day refund for quality issues.
Description
The 24 VDC, 32-Point Discrete Output Module is engineered for reliable performance in industrial automation systems. It offers a high-density output configuration with 32 outputs, organized in groups of 16 points per common, and ensures robust and efficient control for various output devices.
Features
- High Output Capacity: Supports 32 discrete outputs, divided into 16 points per common, ideal for complex automation needs.
- Wide Output Voltage Range: Operates within a 10-31.2 VDC range at 50°C with linear derating, ensuring flexibility and reliability in diverse conditions.
- Configurable Fault and Program States: Allows setting fault states and program mode states to Hold Last State, ON, or OFF for each point, providing enhanced control and safety.
Technical Specifications
- Number of Outputs: 32 (16 points/common)
-
Output Voltage Range:
- 10-31.2 VDC @ 50°C (Linear derating)
- 10-28 VDC @ 60°C
-
Output Current Rating:
- Per Point: 0.5A maximum @ 50°C (Linear derating), 0.35A maximum @ 60°C
- Per Module: 16A maximum @ 50°C (Linear derating), 10A maximum @ 60°C
- Surge Current: 1A for 10ms each, repeatable every 2s @ 60°C
- Flash On Time: 100 µsec target, 150 µsec max
- On-State Current Load (Minimum): 3.0 mA per output
-
On-State Voltage Drop (Maximum):
- 1 VDC @ rated current per point
- 3 VDC for IEC 1131-2
-
Off-State Leakage Current (Maximum):
- 0.5 mA per point
- 1 mA per point for IEC 1131-2 for 0.25 A output
Configurable Settings
- Fault States per Point: Configurable to Hold Last State, ON, or OFF (default OFF)
- States in Program Mode per Point: Configurable to Hold Last State, ON, or OFF (default OFF)
Protection and Safety
- Fusing: Not protected. It is recommended to use Fused IFM to protect outputs.
- Reverse Polarity Protection: None. Incorrect wiring may damage outputs.
Output Delay Time
- Off to On: 1.0 ms maximum
- On to Off: 1.0 ms maximum
Power Dissipation
- Maximum Power Dissipation: 6.1 W
Backplane Current
- Reference: See Module Power Consumption Data, page 46.
Isolation Voltage
- Group to Group: 100% tested at 2546V DC for 1 second (250V AC maximum continuous voltage between groups)
- User to System: 100% tested at 2546V DC for 1 second
Connection
- Terminal Blocks: TC-TBCH, 36-position terminal block